Fsp951 series addressable photoelectric smoke detectors. Read the directions that come with the smoke alarm, they give certain measurements that must be followed for the distance down from the ceiling for a wallmounted detector. In this project, we implemented a simple smoke detector circuit with adjustable sensitivity. The new innovairflex product line is compatible with all previous innovair models, including remote test accessories. It shows the elements of the circuit as simplified forms, and the power as well as signal links in between the gadgets. Initiating device circuits, notification appliance circuits, and signaling line circuits shall be permitted to be designated as either. For detailed installation information, refer to 4098 detectors, sensors, and bases application manual 574709. Di3, dia3 and dib3 ionization smoke detector engineer and architect specifications l adjustable sensitivity l dual chamber l sensitivity test points l simple twistlock assembly l optional auxiliary relay l screwclamp terminals l alarm led l listed, ulc listed, nymea, fm, csfm approved introduction the cerberus pyrotronics di3, dia3 and dib3 fire smoke. Caution smoke detectors are not to be used with detector guards unless the combina tion has been evaluated and found suitable for that purpose. Esl 700 series conventional smoke and heat detector. All of the smoke detector wiring is connected to the fire alarm zone on the panel, and is fully supervised as if it were a single run. This allows you to locate the endofline resistor and power supervision relay at the alarm panel. The electrical sensitivity can be monitored in the field using the cerberus pyrotronics sensitivity tester, test module tmi3.
How to install hardwired smoke detectors the spruce. The esl 500n series conventional twowire and fourwire. Smoke introduced into this air duct system will be distributed throughout the entire building. Wiring diagram for smoke detectors bestharleylinksfo. Should i connect the third wire in the smoke detector to the red wire interconnect. Smoke detectors are not to be used with detector guards unless the combina tion has been evaluated and found suitable for that purpose. These instructions apply to the 4 mounting base part no 45681 200 the 6 mounting base part no 45681 220 the low pro. How to make smoke detector alarm circuit electronics hub. Smoke detector wiring diagram pdf wiring diagram and. System sensor smoke detector wiring diagram free wiring diagram.
The installation of a smoke co alarm should be made by a qualified technician, and all wiring used to install this alarm should be made in accordance with articles 210, and 300. The code does outline some exceptions for situations where a smoke alarm that uses photoelectric detection can be installed closer than 10 ft. The innovairflex duct smoke detector can be customized to meet local codes and specifications without additional wiring. This smoke detector is designed to give early warning of developing fires with an alarm sound from its builtin siren.
The installation of a smokeco alarm should be made by a qualified technician, and all wiring used to install this alarm should be made in accordance with articles 210, and 300. Smoke detectors are amazing devices as they are small, cheap yet very useful. The black and white wires provide the smoke detectors with the power needed to sound an alarm when smoke is detected. The extra run of 4conductor wire gives us a return path to the panel. The next generation of vesda aspirating smoke detection. The detector housing shall be ul listed per ul 268a specifically for use in air handling systems. Vesda vlc500 installation instructions pdf download. Firesmoke barrier doors door releases when tripped by an alarm or smoke detector private offices door releases when triggered by a remote switch all devices come with a wallfloor portion and a door portion armature circuit normally closed door portions have screws and plates to accommodate. The detector shall have a nominal sensitivity of 2. Attach the smoke detector via the threeprong connection in the back of the detector. With power source deenergized and the smoke detector not installed, wire all connections per engineering drawings. The base of smoke detector can be mounted directly onto electrical junction box such as octagonal 3 35 or 4 round 3 and square 4 length box without using any type of mechanical adapter.
Door control for fire and smoke barrier doors and other. Smoke detector wiring diagram download smoke detector wiring diagram wire diagram. We know you expect nothing less when the lives of your family are at. In a consumer product safety commission cpsc survey of households with any fires, including fires in which the fire department was not called, interconnected smoke alarms were more likely to operate and alert occupants to a fire. The sm501 series smoke detector is fitted with a mounting base that will.
Read recommended locations for smoke alarms and locations to avoid for smoke alarms before you begin installation. Duct smoke detectors are not a substitute for open. The detector uses an optical sensing chamber to detect smoke and a. Advanced fire training manual potter electric signal.
Gallery addressable smoke detector wiring diagram pdf saleexpert. When smoke alarms interconnected or not were on all. Ademco vista 20p wiring diagram in smoke detector wiring diagram pdf, image size 961 x 544 px, and to view image details please click the image here is a picture gallery about smoke detector wiring diagram pdf complete with the description of. Important smoke must enter the chamber of the detector. It shows the parts of the circuit as simplified forms, and the power and also signal links in between the tools. A wiring diagram is a simplified traditional pictorial depiction of an electric circuit. Refer to installation instructions 574776 for additional installation detail and maintenance information. Consult the canned smoke agent manu facturers published instructions for any further warnings or caution statements. The eco stax is powered by an external 24v power supply and current.
Smoke detector manual sssd1 introduction the simplisafe smoke detector sssd1 is a photoelectric smoke detector, designed to sense smoke that comes into the detector chamber. Detectors and bases may be mixed on the same initiating loop as long as the number of twowire powered detectors does not exceed the specifications of the control panel see figure 2 below smoke detector data builtin test feature 5fslr24h only 30zone 17. If you have any questions, contact us using the contact information on page 8. Sep 26, 2017 how to wire a 2wire smoke detector on paradox evo alarm panels using pgm1 as input. Twowire photoelectric smoke detector, with remote test input and remote alarmtrouble led output. The sensitivity test jack on the di3, dia3 and dib3 and the adjustment screw on the di3 are accessible from the front of the detector housing. It shows the components of the circuit as streamlined forms, as well as the power and signal links between the tools. A wiring diagram is a simplified standard photographic representation of an electrical circuit. Model d4120 and d4s duct smoke detectors utilize 4wire photoelectric tech nology for the detection of smoke. Esl 500n series smoke detector installation sheet description note.
The wiring terminal blocks are external to the eco detectors providing easy field wiring. When used properly, the canned smoke agent will cause the smoke detector to go into alarm. Using this photoelectric smoke detector circuit can be designed a very simple and low power smoke detector alarm project that is based on the re46c190 smoke detector ic. Connect wiring to the bases as shown in the wiring diagrams that follow. Application guide, which provides detailed information on detector spacing, placement, zoning, wiring. Figure 1b shows the typical wiring diagram of the 4wire multiplestation smokeheat detector system. Wiring installation guidelines all wiring must be installed in compliance with the national electrical code, applicable state and local codes, and any special requirements of the local. This document provides guidance for the proper operation of fire detection systems for those who apply, install, and maintain them. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. Model d355pl air duct smoke detector utilizes photoelectric technology for the detection of smoke. I have connected white to white and black to black. This smoke alarm is designed to be mounted on any standard wiring junction box to a 4inch 10 cm size, on either the ceiling or wall.
Read the system sensor guide for proper use of smoke detectors in duct appli cations a051004, which provides detailed information on detector spacing, placement, zoning, wiring, and special applications. Fsp951 series detectors are available for both flashscan and clip applications as designated. For sl2000 series duct smoke detectors youyou in control i n. Smoke detector wiring connections electrical wiring. Kidde i4618ac alarm hardwire smoke detector with 9v backup and front load battery door model i4618. You can trust this product to provide the highest quality safety. Note 1 this component is the fire resistor, and its value is specified by the fire control. Page 1 page 2 page 3 page 4 page 5 wiring instructions page 6 battery installation page 7. We cannot provide technical support to unqualified persons. For a single smoke detector used in single level homes or apartments, the yellow wire. This smoke alarm is designed to be mounted on any standard wiring junction box up to a 4inch 10 cm size, on either the ceiling or wall if allowed by local codes. The detector shall allow prewiring of the base and the head shall be a plugin type. A smoke detector is a device that senses smoke, typically as an indicator of fire.
With all wiring in place, install the detector head. The detector uses an optical sensing chamber to detect smoke and a fixedtemperature heat sensor to detect heat from fire. Assortment of system sensor smoke detector wiring diagram. Misuse or overuse of these products may have long term adverse effects on the smoke detector.
When a special application for a reduced sensitivity. The trouble contact supervises the presence of the input power, removal of the detector cover and the removal of the smoke detector head. The sensitivity of the di3, dia3 and dib3 is preset at the factory. Up to three eco stax can be used with one 4pipe vesdae detector. The duct unit supports two sets of form c alarm contacts, one form a alarm contact and one form c trouble contact. When provided with detector, it is designed to sample the air flow.
Once a smoke detector s wires are properly connected to the wiring on the wall or the ceiling, screw it tightly on the wall or the ceiling. System sensor smoke detector wiring diagram free wiring. Bg electrical smoke detectors have an interconnectable of up to 23 alarms on the same wiring network. The fsp951r is a remote test capable detector for use with dnr series duct detector housings.
Esl 700 series conventional smoke and heat detector installation sheet description the esl 700 series smoke or smoke with rateofrise heat detectors have fieldreplaceable optical chambers. A typical construction project will require a smoke detector in each bedroom and on the ceiling or wall at a point centrally located in the area giving access to bedrooms such as hallways. Red led four modes of operation tamper resist features wiring instructions mounting battery installation and removal. The fsp951 series detector sensitivity can be programmed in the control panel software. Esl 700 series conventional smoke and heat detector installation. A pulsed infrared lightemitting diode serves as the light source, and a. Open area smoke detectors are intended for mounting on a ceiling or a wall in accordance with the fire standard in your country. Canned aerosol simulated smoke canned smoke agent formulas will vary by manufacturer.
The effectiveness of a duct smoke detector is highly dependent upon. We used a smoke sensor mq2 as the main sensory device. How to wire a 2wire smoke detector on paradox evo alarm panels using pgm1 as input. Once a smoke detectors wires are properly connected to the wiring on the wall or the ceiling, screw it tightly on the wall or the ceiling. Wiring installation guidelines all wiring must be installed in compliance with the national electrical code, applicable state and local codes, and any special requirements of the local authority having. The eco stax contains four standard eco detectors with the necessary manifolds to hold them in place. Mount smoke detectors at least 4 inches from wall or on the wall with the top of the detector within 4 inches and 12 inches of the highest point of the.
Smoke detectors designed for use in air duct systems are used to sense the presence of smoke in the duct. An automatic fire alarm systemtypically made up of smoke detectors, heat detectors, manual pull stations, audible warning devices, and a fire alarm control panel. For 4 wire smoke detector wiring, running an extra 4conductor wire gives the same effect. The duct unit supports two sets of form c alarm contacts and one form c trouble contact. Put the smoke detector mounting bracket on the box, aligning it with the two screw holes. Wiring diagram for connection of a single conventional detector to a zone. For additional details on making wiring connections to smoke detector terminals, check out smoke detector circuit basics. Figure 1b shows the typical wiring diagram of the 4wire multiplestation smoke heat detector system. My hard wired smoke alarm system has red black, white wires leading to the smoke alarm. Kidde alarms and accessories can only be interconnected with other kidde. These installation instructions provide essential information for installing vesda vlc aspirating smoke detectors in accordance with the system design. The air duct smoke detector shall be a system sensor innovairflex d4120 photoelectric duct smoke detector. Twowire slc loop connection unit uses base for wiring compatible with flashscan and clip protocol systems.
A wiring diagram is a simplified traditional photographic depiction of an electric circuit. When provided with detector, it is designed to sample the air flow passing by it in the air duct to determine whether it contains unacceptable levels of smoke. This document is intended for licensed electricians or alarm installers. Variety of fire alarm smoke detector wiring diagram. The flexible housing of the duct smoke detector fits multiple footprints from square to rectangular. Ademco vista 20p wiring diagram in smoke detector wiring diagram pdf, image size 961 x 544 px, and to view image details please click the image here is a picture gallery about smoke detector wiring diagram pdf complete with the description of the image, please find the image you need. Commercial security devices issue a signal to a fire alarm control panel as part of a fire alarm system, while household smoke detectors, also known as smoke alarms, generally issue a local audible or visual alarm from the detector itself or several detectors if there are multiple smoke detectors interlinked. The 40989601 standard sensitivity detector is recommended for most applications. The working of the circuit is simple and is explained below. With minimal external components, this smoke detectors alarm circuit will provide all the required features for a photoelectric smoke detector type electronic project.